Mistake-resistant sockets
Mechanical shutters physically block lead combinations that conflict with the selected function.
A German-made 60,000-count professional TRMS meter with patented terminal shutters, a 2 MB logger, CAT IV 600 V protection and a DAkkS calibration certificate.
$650.00
Please read How we make money.
The current exact successor to the database's older “METRAHIT X-TRA” name is the M250A METRAHIT PM XTRA. It is a 60,000-count, 0.05%-basic-accuracy TRMS meter with 26 functions, AC+DC measurement, 100 kHz voltage bandwidth and a 1 MHz logic-level frequency input. A 2 MB logger stores up to 61,600 va...
$650.00
In Stock
The features that make this product stand out from the competition.
Mechanical shutters physically block lead combinations that conflict with the selected function.
The included DAkkS certificate and stable 60,000-count platform suit controlled maintenance programs.
The 2 MB memory stores tens of thousands of readings without tethering the meter during capture.
Gossen documents 60,000 counts, 0.05% basic accuracy and 100 kHz voltage TRMS bandwidth.
AI-assisted preliminary estimate pending editor review and durable-source evidence.
The exact model has automatic blocking sockets, separate fuse/battery access, IP52 housing and CAT IV 600 V rating.
AI-assisted preliminary estimate pending editor review and durable-source evidence.
AI-assisted preliminary estimate pending editor review and durable-source evidence.
AI-assisted preliminary estimate pending editor review and durable-source evidence.
AI-assisted preliminary estimate pending editor review and durable-source evidence.
AI-assisted preliminary estimate pending editor review and durable-source evidence.
AI-assisted preliminary estimate pending editor review and durable-source evidence.
AI-assisted preliminary estimate pending editor review and durable-source evidence.
Gossen Metrawatt's current German product documentation specifies 36 months against defects.
AI-assisted preliminary estimate pending editor review and durable-source evidence.
AI-assisted preliminary estimate pending editor review and durable-source evidence.
AI-assisted preliminary estimate pending editor review and durable-source evidence.
AI-assisted preliminary estimate pending editor review and durable-source evidence.
The sticker price is just the beginning. Use this tool to estimate the true long-term cost of this product. Adjust the sliders based on your expected usage and care to see how the value holds up over time.
Based on your estimates, the true cost is:
$38.63
Per Year
$579.50
Over 15 years
Observed US merchant prices in USD.
Sign in to view tracked price history
See recorded merchant prices and changes over time.
Sign in to view price historyThe PM XTRA supports DC, AC TRMS, and AC+DC TRMS voltage and current measurements, plus resistance, continuity, diode, frequency, duty-cycle, temperature, capacitance, and dB functions. Temperature can be measured with Type K thermocouples or Pt100/Pt1000 sensors. The instrument also provides relative, zero, and MIN/MAX/DATA functions.
Yes. Gossen’s PM-series datasheet describes a function for measuring the frequency and duty cycle of 2–5 V square-wave signals, such as transmission or logic-level signals. For the PM XTRA, the specified frequency range reaches up to 1 MHz, and duty-cycle measurement is specified from 2% to 98%.
The meter uses three connector jacks and routes all current ranges through a single current jack. Its automatic blocking sockets are linked to the rotary switch and prevent incompatible lead positions and incorrect range selections, reducing the risk of damage to the meter, the circuit under test, or the operator from connection errors.
The PM XTRA provides direct current ranges from 600 µA through 6 mA, 60 mA, 600 mA, 6 A, and 10 A. The technical data specify a 10 A limit for up to five minutes and a 16 A limit for up to 30 seconds under the stated conditions; these limits should not be treated as a general substitute for the instrument’s safety-category requirements.
The selectable 1 kHz low-pass filter is available for AC-voltage measurements, including work such as measuring motor voltage at electronic frequency converters. When the filter is active, the input is checked for dangerous voltage by a comparator, and the display shows a high-voltage symbol when such voltage is detected.
The meter can switch off automatically when the measured value remains unchanged and no controls are used. The datasheet specifies an adjustable delay of 10 to 59 minutes. It also states that automatic shutdown can be disabled by selecting continuous-operation mode, which is useful for unattended logging or extended bench work.
Yes. The PM-series documentation describes use with current clamps and sensors, allowing current measurement without interrupting the circuit and supporting currents above 16 A. An adjustable transfer factor lets the meter convert the sensor output into a current reading; the clamp or sensor’s own limits and accuracy remain applicable.